LBT2 condensing unit SERIES

Air-cooled condensing units - Tropicalized - AC fans

LBT2 series

Tropical climates are no match for Frascold’s LBT2 Series of air-cooled condensing units. These units are specifically designed to meet the needs of commercial refrigeration in higher temp locales.

Excellent reliability
Comprehensive service
Compact design
Easy installation
Silent
Highlights

LBT2 SERIES

Frascold offers a diverse line-up of LBT2 air-cooled condensing units made to meet the unique needs of commercial applications in tropical climates. Efficiency in design yields a compact unit ready for installation in small spaces and particularly urban environments where noise level needs to be controlled and restricted.

The LBT2 air-cooled condensing units are the ideal solution in a variety of cooling systems such as cold rooms, supermarkets, shops, distribution centers, industrial applications, and process cooling for food production/storage.

Recommended applications
Frozen food outlets
Retail outlets
Wineries
Cultivations
Hyper-super market
Features
Advantages
Reliable to Operate

Frascold LBT2 condensing units are crafted with excellence and each unit is meticulously tested before ever leaving our facilities. We test each unit for functionality, integrity, and safety using state-of-the-art precision testing machines to guarantee extremely high levels of quality and reliability. Adding our optional protection system with Diagnose® technology allows issues such as faults to be detected early and then resolved quickly all to help reduce maintenance and downtime.

Made to Be Quiet

The Frascold LBT2 Series is going to stand out for just how quiet these units are. With a unique external structure, advanced mechanical components, and a dynamic electric motor, these units are whisper-quiet during operation. This makes them perfect for urban areas and can be installed close to their use which helps limit the potential risk for pressure drops.

Provides Energy Savings

The LBT2 air-cooled condensing units utilize an innovative design within Frascold’s semi-hermetic compressors along with precise sizing of all the components used to streamline energy consumption.

Easy to Install and Maintain

Our design was engineered to make installing LBT2 air-cooled condensing units simple and straightforward. Easier access to important components means future maintenance tasks can be undertaken quicker and safer than ever.

Fully Supported By Frascold’s Global Network

The Frascold customer service team is dedicated to exceeding our clients’ expectations before, during, and especially after the sale. Immediate assistance is always available to help in the event of crisis. We support our clients directly and through our global network of support centers and services partners located around the world.

Do you need a customized solution?

We are always available to advise you on the best refrigeration solution for your business. Talk to our experts

Technical Data

Performance and versatility

@ T. Environment 89,6°F

Cooling capacity

Size A

Size A
Volumetric displacement
2,4 - 4,1 CFM
Motor power
0,4 - 1,1 kW
5 Available models

Main technical data

Volumetric displacement2,4 CFM
Motor power0,4 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement2,9 CFM
Motor power0,5 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement3,2 CFM
Motor power0,7 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement4,1 CFM
Motor power0,7 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement4,1 CFM
Motor power1,1 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size B

Size B
Volumetric displacement
5,3 - 5,8 CFM
Motor power
1,1 - 1,5 kW
2 Available models

Main technical data

Volumetric displacement5,3 CFM
Motor power1,1 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement5,8 CFM
Motor power1,5 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size D

Size D
Volumetric displacement
6,7 - 10,5 CFM
Motor power
1,5 - 3 kW
7 Available models

Main technical data

Volumetric displacement6,7 CFM
Motor power1,5 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement7,8 CFM
Motor power1,5 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement7,8 CFM
Motor power2,2 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement9,7 CFM
Motor power2,2 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement9,7 CFM
Motor power3 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement10,5 CFM
Motor power2,2 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement10,5 CFM
Motor power3 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size Q

Size Q
Volumetric displacement
11,7 - 21,1 CFM
Motor power
3 - 5,2 kW
9 Available models

Main technical data

Volumetric displacement11,7 CFM
Motor power3 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement12,5 CFM
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement14,1 CFM
Motor power3 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement14,1 CFM
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement16,5 CFM
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement16,5 CFM
Motor power5,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement19,2 CFM
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement19,2 CFM
Motor power5,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement21,1 CFM
Motor power5,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size S

Size S
Volumetric displacement
24,3 - 33,0 CFM
Motor power
6 - 11,2 kW
5 Available models

Main technical data

Volumetric displacement24,3 CFM
Motor power6 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement24,3 CFM
Motor power8,9 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement30,3 CFM
Motor power7,5 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement30,3 CFM
Motor power11,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement33,0 CFM
Motor power11,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Are you an installer or a refrigeration technician?

Rely on our software to search for spare parts or find the ideal compressor for your application.