EBT series

The EBT series of air-cooled condensing units are designed specifically to meet the increased demand for commercial sector applications in areas that experience higher temperatures.

Excellent reliability
Comprehensive service
Compact design
Easy installation
Silent
Highlights

EBT SERIES

Frascold’s EBT Series of air-cooled condensing units are ideal for tropical climates. The innovative design fits perfectly for compact installations in small spaces and urban environments. These areas require forward-minded design features as noise level needs to be reduced and the energy consumption must be controlled.

The EBT Series provides both of these and so much more all within a single air-cooled condensing unit. The EBT air-cooled condensing units are ideally suited for use in cooling systems such as cold rooms, supermarkets, shops, distribution centers, industrial applications, and process cooling in the food production and food storage industries.

Recommended applications
Frozen food outlets
Retail outlets
Wineries
Cultivations
Hyper-super market
Features
Advantages
Dependable Operation

Frascold EBT condensing units are meticulously designed and assembled before being rigorously tested using the most technologically-advanced testing systems available today. We’re persnickety about quality in everything we do so that our clients know the condensing unit they receive is going to perform well no matter what. An optional protection system with Diagnose® technology can be utilized on every Frascold condensing unit in this series to allow any faults to be detected early and quickly resolved, helping to minimize maintenance and downtime.

Peace & Quiet

The EBT Series condensing units stand out for being extremely quiet, especially under partial loads. This advancement has been made with a unique external structure, cutting-edge mechanical components, and innovative EC electric fans. These units can even be installed in urban areas and in areas very close to their intended use, which also helps reduce any potential risks of pressure drops.

Energy Savings, Anyone?

The ultra-high efficiency levels achieved by every EBT air-cooled condensing unit are due to the ingenious design of the Frascold semi-hermetic compressors, the precise sizing of all the components used, and also through the ability to regulate the speed of the fans with an electronic device.

Near Effortless Installation and Maintenance

Thanks to the advanced design structure, installing EBT air-cooled condensing units is extremely simple and fast. Providing easy access to all the components makes carrying out future maintenance tasks a quick and safe operation.

Unsurpassed Customer Support

The Frascold customer service is trained and ready for one purpose – to assist our customers through every stage of design, installation, and maintenance of their new system. We provide both direct assistance and have the ability to tap an extensive support network of support centers and service partners throughout the world.

Do you need a customized solution?

We are always available to advise you on the best refrigeration solution for your business. Talk to our experts

Technical Data

Performance and versatility

@ T. Environment 89,6°F

Cooling capacity

Size A

Size A
Volumetric displacement
4 - 6,9 m³/h
Motor power
0,4 - 1,1 kW
5 Available models

Main technical data

Volumetric displacement4 m³/h
Motor power0,4 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement4,9 m³/h
Motor power0,5 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement5,5 m³/h
Motor power0,7 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement6,9 m³/h
Motor power0,7 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement6,9 m³/h
Motor power1,1 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size B

Size B
Volumetric displacement
9 - 9,9 m³/h
Motor power
1,1 - 1,5 kW
2 Available models

Main technical data

Volumetric displacement9 m³/h
Motor power1,1 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement9,9 m³/h
Motor power1,5 kW
Pistons2
Cap. reg.100

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size D

Size D
Volumetric displacement
11,3 - 17,9 m³/h
Motor power
1,5 - 3 kW
7 Available models

Main technical data

Volumetric displacement11,3 m³/h
Motor power1,5 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement13,1 m³/h
Motor power1,5 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement13,1 m³/h
Motor power2,2 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement16,4 m³/h
Motor power2,2 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement16,4 m³/h
Motor power3 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement17,9 m³/h
Motor power2,2 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement17,9 m³/h
Motor power3 kW
Pistons2
Cap. reg.100-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size Q

Size Q
Volumetric displacement
19,8 - 35,9 m³/h
Motor power
3 - 5,2 kW
9 Available models

Main technical data

Volumetric displacement19,8 m³/h
Motor power3 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement21,2 m³/h
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement23,9 m³/h
Motor power3 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement23,9 m³/h
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement28 m³/h
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement28 m³/h
Motor power5,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement32,7 m³/h
Motor power3,7 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement32,7 m³/h
Motor power5,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement35,9 m³/h
Motor power5,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Size S

Size S
Volumetric displacement
41,3 - 56 m³/h
Motor power
6 - 11,2 kW
5 Available models

Main technical data

Volumetric displacement41,3 m³/h
Motor power6 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement41,3 m³/h
Motor power8,9 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement51,5 m³/h
Motor power7,5 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement51,5 m³/h
Motor power11,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Main technical data

Volumetric displacement56 m³/h
Motor power11,2 kW
Pistons4
Cap. reg.100-75-50

Need more information?

Access the documentation section to download data sheets, installation manuals and certifications of this model.

Are you an installer or a refrigeration technician?

Rely on our software to search for spare parts or find the ideal compressor for your application.